Comprehensive Service Contract
Emergency Service | Financing and Warranties Available
Give yourself the peace of mind that you will receive priority service in a timely manner. Please give us a call or send a note to get pricing for your application. Service will be performed along the following guidelines. These are used for all service plans to ensure consistency through all maintenance visits.
| DESCIPTION OF SERVICE. System service will be performed along A/C Heat Gas Oil these following guidelines. These are used for all service plans to Pump Furnace Furnace ensure consistency through all maintenance visits. |
A/C | Heat Pump | Gas Furnace | Oil Furnace |
| Test fire/cycle all units to ensure initial operation upon arrival | ||||
| Check temperature splits/rises, compare to manufacturers specs | ||||
| Verify refrigeration pressures with manufacturers charts and data | ||||
| Verify superheat (orifice) and subcooling (TXV) readings per manufacturers charts and data sheets | ||||
| Inspect contactor points for burnt or pitted contacts | ||||
| Inspect wiring for chafes/nicks/cuts/hot spots/burnt connectors | ||||
| Check line voltage for amp draw on all motors and compressors, tighten all connectors | ||||
| Check operation of fan relays | ||||
| Check operation of electric heaters, fuse links and crankcase heaters | ||||
| Check reversing valve operation | ||||
| Check defrost sensor and inspect contact lines | ||||
| Manual defrost test on board (outdoor temperatures permitting) | ||||
| Verify proper dip switch settings on variable speed (first time) | ||||
| Verify proper blower speed on 3 speed (first time) | ||||
| Verify proper low voltage wiring (first time). Corrections are additional labor/cost | ||||
| Oil motors when oil-able | ||||
| Inspect fan blades and wheels for deterioration/cracks | ||||
| Flush and blow out drains, clean and test condensate pump. Inspect drains to ensure proper installation of traps & serviceability of parts. | ||||
| Replace disposable filters (customer provided) or clean re-usable filters. Media type air filters are an additional cost | ||||
| Clean indoor coils (where accessible) and clean outdoor coils | ||||
| Check thermostat operation | ||||
| Assess exposed duct system | ||||
| Check level/pitch on indoor and outdoor units | ||||
| Inspect heat exchangers for cracks or deterioration, vacuum out soot and dirt from heat exchanger | ||||
| Remove venting and inspect/clean chimney base | ||||
| Replace nozzle, oil filter, pump strainer and associated gaskets. Clean nozzle assembly, inspect burner coupling | ||||
| Remove and clean burners and orifices | ||||
| Inspect pressure switch, tubing and connections | ||||
| Remove and clean flame sensor, inspect ignitor and test readings | ||||
| Check and set inlet/outlet gas pressures, adjust to manufacturers specs | ||||
| Inspect fuel line installation and bonding, note any abnormalities | ||||
| Run and check burner operation, perform combustion test and adjust settings for maximum efficiency, document all readings | ||||
| Verify all operations and safeties on equipment | ||||
| Cleanup the work area, remove all trash and material used |